Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Rev. bras. ginecol. obstet ; 44(3): 238-244, Mar. 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1387883

RESUMO

Abstract Objective To analyze the historical clinical outcomes of children with myelomeningocele (MMC) meeting the criteria for fetal surgery, but who underwent postnatal primary repair. Methods Data from children undergoing postnatal MMC repair between January 1995 and January 2015 were collected from the Neurosurgery Outpatient Clinic's medical records. Children were included if they had ≥1 year of postoperative follow-up andmet the criteria for fetal surgery. The children's data were then stratified according to whether they received a shunt or not. The primary outcome was mortality, and secondary outcomes were educational delays, hospitalization, recurrent urinary tract infections (UTIs), and renal failure. Results Over the 20-year period, 231 children with MMC were followed up. Based on clinical data recorded at the time of birth, 165 (71.4%) qualify of fetal surgery. Of the 165 patients, 136 (82.4%) underwent shunt placement. The mortality rate was 5.1% in the group with shunt and 0% in the group without, relative risk (RR) 3.28 (95% confidence interval, 95% CI, 0.19-55.9). The statistically significant RRs for adverse outcomes in the shunted group were 1.86 (95% CI, 1.01-3.44) for UTI, 30 (95% CI, 1.01-537) for renal failure, and 1.77 (95% CI, 1.09-2.87) for hospitalizations. Conclusion Children with MMC qualifying for fetal surgery who underwent shunt placement were more likely to have recurrent UTIs, develop renal failure, and be hospitalized. Since approximately half of the shunt procedures could be avoided by fetal surgery, there is a clinical benefit and a possible financial benefit to the implementation of this technology in our setting.


Resumo Objetivo Analisar os resultados clínicos históricos de crianças commielomeningocele (MMC) com critérios para cirurgia fetal,mas que foram submetidas a cirurgia pós-natal. Métodos Dados de crianças submetidas à correção deMMCpós-natal entre janeiro de 1995 e janeiro de 2015 foram coletados nos prontuários do Ambulatório de Neurocirurgia. Foram incluídas crianças se tivessem ≥ 1 ano de acompanhamento pósoperatório e atendessem os critérios para cirurgia fetal. As informações dessas crianças foram então estratificadas de acordo com se receberam ou não derivação do líquido cefalorraquidiano. O desfecho primário foi a mortalidade e os desfechos secundários foram atrasos educacionais, hospitalização, infecções recorrentes do trato urinário einsuficiência renal. Resultados Durante o período de 20 anos, 231 crianças com MMC foram acompanhadas. Com base nos dados clínicos registrados no momento do nascimento, 165 (71,4%) atendiam critérios para a cirurgia fetal. Dos 165 pacientes, 136 (82,4%) foram submetidos à colocação de derivação do líquido cefalorraquidiano. A taxa de mortalidade foi de 5,1% no grupo com derivação do líquido cefalorraquidiano e 0% no grupo sem risco relativo (RR) 3,28 (intervalo de confiança 95%, IC 95%, 0,19-55,9). Os RRs estatisticamente significativos para resultados adversos no grupo com derivação do líquido cefalorraquidiano foram 1,86 (IC 95%, 1,01-3,44) para infecção do trato urinário, 30 (IC 95%, 1,01-537) para insuficiência renal e 1,77 (IC 95%, 1,09-2,87) para hospitalizações. Conclusão Crianças com MMC com critérios para cirurgia fetal submetidas à colocação de derivação do líquido cefalorraquidiano eram mais propensas a ter infecções recorrentes do trato urinário, desenvolver insuficiência renal e serem hospitalizadas. Como aproximadamente metade dos procedimentos de derivação poderiam ser evitados por cirurgia fetal, há um benefício clínico e um possível benefício financeiro com a implementação dessa tecnologia em nosso meio.


Assuntos
Humanos , Pré-Escolar , Derivações do Líquido Cefalorraquidiano , Disrafismo Espinal , Meningomielocele , Feto/cirurgia
3.
Rev. bras. ginecol. obstet ; 42(5): 289-296, May 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1137828

RESUMO

Abstract Intrauterine growth restriction (IUGR) is associated with poor perinatal prognosis and a higher risk of stillbirth, neonatal death, and cerebral palsy. Its detection and the evaluation of its severity by new Doppler velocimetric parameters, such as aortic isthmus (AoI), are of great relevance for obstetrical practice. The AoI is a vascular segment that represents a point of communication between the right and left fetal circulations. It is considered to be a functional arterial shunt that reflects the relationship between the systemic and cerebral impedances, and has recently been proposed as a tool to detect the status of hemodynamic balance and prognosis of IUGR in fetuses. In the present review, we noticed that in healthy fetuses, the AoI net flow is always antegrade, but in fetuses with IUGR the deterioration of placental function leads to progressive reduction in its flow until it becomes mostly retrograde; this point is associated with a drastic reduction in oxygen delivery to the brain. The more impaired the AoI flow is, the greater is the risk of impairment in the Doppler velocimetry of other vessels; and the alterations of the AoI Doppler seem to precede other indicators of severe hypoxemia. Although there seems to be an association between the presence of retrograde flow in the AoI and the risk of long-term neurologic disability, its role in the prediction of perinatal morbi-mortality remains unclear. The AoI Doppler seems to be a promising tool in the management of fetuses with IUGR, but more studies are needed to investigate its employment in clinical practice.


Resumo O crescimento intrauterino restrito (CIUR) está associado a um prognóstico perinatal adverso, com maior risco de óbito intrauterino e neonatal, bem como de paralisia cerebral. Assim, sua detecção e a determinação de sua gravidade por novos parâmetros Dopplervelocimétricos, como o istmo aórtico (IAo), são de fundamental importância na prática obstétrica. O IAo é um segmento vascular que representa um ponto de comunicação entre os sistemas circulatórios fetais esquerdo e direito. É considerado um shunt arterial funcional, capaz de refletir a relação entre as impedâncias dos circuitos cerebral e sistêmico, e foi proposto como uma ferramenta para detecção do status do equilíbrio hemodinâmico e do prognóstico de fetos com CIUR. Na presente revisão, observou-se que, em fetos saudáveis, o fluxo predominante no IAo é sempre anterógrado; mas em fetos com CIUR a deterioração do estágio de insuficiência placentária acarreta reduções progressivas no fluxo ístmico até este apresentar sentido predominantemente retrógrado e levar a uma drástica redução no aporte de oxigênio ao sistema nervoso central. Quanto mais alterado estiver o fluxo no IAo, maior a chance de haver alteração na Dopplervelocimetria de outros vasos; e as alterações no Doppler do IAo parecem preceder outros indicadores de hipoxemia severa. Embora o fluxo retrógrado no IAo pareça se correlacionar com maior risco de alteração no desenvolvimento neurológico a longo prazo, ainda não está claro o seu papel na predição de morbimortalidade perinatal. O Doppler do IAo parece ser um parâmetro promissor no manejo do CIUR; entretanto, mais estudos são necessários para avaliar seu emprego na prática clínica.


Assuntos
Humanos , Feminino , Gravidez , Recém-Nascido , Aorta Torácica/diagnóstico por imagem , Ultrassonografia Pré-Natal , Retardo do Crescimento Fetal/diagnóstico por imagem , Feto/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Ultrassonografia Doppler , Retardo do Crescimento Fetal/fisiopatologia , Feto/irrigação sanguínea
4.
Rev. bras. ginecol. obstet ; 40(10): 580-586, Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977775

RESUMO

Abstract Objective To assess 11 formulae commonly used to estimate fetal weight in a population of premature fetuses who had abnormal Doppler velocimetry due to early-onset placental insufficiency. The performance of each formula was evaluated in subgroups of fetuses with expected growth and intrauterine growth restriction. Methods Data were collected fromfetuses andmothers who delivered at three Brazilian hospitals between November 2002 and December 2013.We used the following formulae: Campbell; Hadlock I, II, III, IV and V; Shepard; Warsof; Weiner I and II; and Woo III. Results We analyzed 194 fetuses. Of these, 116 (59.8%) were considered appropriate for gestational age (AGA), and 103 (53.1%) were male. The amniotic fluid volume was reduced in 87 (44.8%) fetuses, and the umbilical artery Doppler revealed absence or inversion of diastolic flow in 122 (62.9%) cases, and the analysis of the ductus venosus revealed abnormal flow in 60 (34.8%) fetuses. The Hadlock formulae using three or four fetal biometric parameters had low absolute percentage error in the estimated fetal weight among preterm fetuses with abnormal Doppler studies who were born within 5 days of the ultrasound evaluation. The results were not influenced by the clinical and ultrasound parameters often found in early-onset placental insufficiency. Conclusion In this study, the formulae with the best performance for fetal weight estimation in the analyzed population were Hadlock I and IV, which use four and three fetal biometric parameters respectively to estimate the weight of preterm fetuses with abnormal Doppler studies.


Resumo Objetivo Avaliar o desempenho de 11 fórmulas comumente utilizadas para estimativa de peso fetal em uma população de fetos prematuros com dopplervelocimetria alterada devido a insuficiência placentária de início precoce. O desempenho de cada fórmula foi avaliado em subgrupos de fetos com crescimento adequado e com crescimento intrauterino restrito. Métodos Foram coletados os dados de mães e fetos cujos partos foram acompanhados em 3 instituições brasileiras entre novembro de 2002 e dezembro de 2013. As fórmulas selecionadas para análise foram: Campbell; Hadlock I, II, III, IV e V; Shepard; Warsof; Weiner I e II; e Woo III. Resultados Foram analisados os pesos de 194 fetos, dos quais 116 (59,8%) foram considerados adequados para a idade gestacional, 103 (53,1%) eram do sexo masculino, em 87 (44,8%) havia redução do volume de líquido amniótico, em 122 (62,9%) o Doppler de artéria umbilical demonstrou ausência ou inversão do fluxo na diástole, e em 60 (34,8%) a análise do duto venoso indicou fluxo anormal. A média do erro percentual absoluto (EPA) demonstrou que as fórmulas de Hadlock que utilizam 3 ou 4 parâmetros biométricos fetais apresentaram o melhor desempenho. Os resultados obtidos para essas fórmulas não sofreram influência dos parâmetros clínicos e ultrassonográficos frequentemente encontrados na insuficiência placentária de início precoce. Conclusão O presente estudo demonstrou o melhor desempenho das fórmulas de Hadlock que contêm 3 ou 4 parâmetros da biometria para estimativa de peso de fetos prematuros com anormalidades ao mapeamento Doppler.


Assuntos
Humanos , Feminino , Gravidez , Pesos e Medidas Corporais/métodos , Ultrassonografia Pré-Natal , Ultrassonografia Doppler , Peso Fetal , Reologia , Estudos Retrospectivos , Idade Gestacional , Nascimento Prematuro
5.
Femina ; 46(2): 124-130, 20180430. ilus
Artigo em Português | LILACS | ID: biblio-1050111

RESUMO

Objetivo: O crescimento intrauterino restrito (CIUR) por insuficiência placentária persiste como grande desafio obstétrico. A interrupção da gestação representa a única estratégia de condução e baseia-se na predição de desfechos adversos. O Doppler tem valor reconhecido na avaliação seriada das alterações circulatórias nesses fetos, em geral sequenciais e proporcionais à gravidade do insulto hipóxico. Este estudo objetiva revisar as evidências do papel do Doppler de ducto venoso (DV) na predição de morbimortalidade perinatal em gestações complicadas por CIUR placentário grave e precoce. Métodos: Realizou-se revisão narrativa, com busca de artigos publicados nos últimos 10 anos nas bases Medline/PubMed, Lilacs e Scielo, sendo encontradas 132 referências. Pesquisas com animais e gestações múltiplas foram excluídas. Dos 115 artigos selecionados, 34 foram excluídos por inadequação ao tema. A revisão baseou-se nas demais 81 referências, além de trabalhos de reconhecida relevância no tema. Resultados: Estudos demonstram evidência consistente do papel do Doppler de DV na avaliação de fetos com CIUR, com bom valor preditivo para acidemia fetal e desfecho perinatal adverso. As principais estratégias de monitorização se baseiam na combinação do Doppler de vasos arteriais/venosos e parâmetros biofísicos, mas o Doppler de DV seria o melhor parâmetro isolado para predição de comprometimento fetal grave. Conclusão: A incorporação do Doppler de DV na monitorização de fetos com CIUR grave e precoce é capaz de predizer desfechos perinatais críticos. A avaliação de múltiplos vasos fetais parece aumentar a acurácia, porém não há evidência para embasar a definição de protocolos para o manejo clínico.(AU)


Objective: Intrauterine growth restriction (IUGR) due to early onset placental insufficiency remains to be a great challenge in obstetrical practice. Delivery is still the only available strategy of management, and timing such intervention depends on prediction of adverse outcomes. Dopplervelocimetry studies have recognized value in the evaluation of the sequential hemodynamic changes that are stablished in the arterial and venous circulation of these fetuses, which correlate with the severity of hypoxemic insult. This study aims to review evidence on ductus venosus (DV) Doppler`s role as a predictor of perinatal outcome in pregnancies complicated by severe early onset IUGR. Methods: A Medline/PubMed, Lilacs and Scielo search was performed to identify original articles and systematic reviews published in the last 10 years. Eighty-one references were included in this review, in addition to other papers of recognized relevance in the subject. Results: Studies demonstrate consistent evidence on DV Doppler`s role in the longitudinal evaluation of IUGR fetuses, with adequate predictive value for fetal acidemia and adverse outcome. Monitoring strategies are usually based on a combination of arterial and venous Doppler assessment, in addition to biophysical parameters, but DV Doppler seems to be the best single parameter for prediction of severe fetal compromise. Conclusion: Monitoring of fetuses with severe early-onset IUGR through DV Doppler is able to predict critical perinatal outcomes. Evaluation of multiple fetal vessels seems to increase accuracy of prediction, but to this moment there is not enough evidence to recommend protocols of management.(AU)


Assuntos
Humanos , Feminino , Gravidez , Ultrassonografia Doppler/métodos , Retardo do Crescimento Fetal/fisiopatologia , Retardo do Crescimento Fetal/diagnóstico por imagem , Circulação Sanguínea , Bases de Dados Bibliográficas , Ultrassonografia Pré-Natal/métodos , Hipóxia Fetal/diagnóstico por imagem , Monitorização Fetal/métodos
6.
Femina ; 44(4): 224-232, dez. 30, 2016. ilus
Artigo em Português | LILACS | ID: biblio-1050869

RESUMO

Ocrescimento intrauterino restrito (CIUR) é uma inibição patológica do crescimento fetal, acometendo 5-10% das gestações e está associado ao aumento da morbimortalidade perinatal. Este estudo tem como objetivo realizar uma revisão não sistemática sobre os eventos adversos perinatais dos fetos com CIUR tardio e alteração seletiva do Doppler da artéria cerebral média (ACM). A pesquisa bibliográfica foi realizada através da base de dados do PubMed, obtendo um total de 25 referências, que serviram de base para o presente artigo. Conclui-se que a artéria cerebral média possui valor particular na identificação e predição de resultados adversos nestes fetos, os quais possuem risco aumentado de desenvolvimento neurológico anormal ao nascimento e aos dois anos de idade.(AU)


Intrauterine growth restriction (IUGR) is a pathological inhibition of the fetal growth that affects 5-10% of pregnancies and it is associated with an increase of perinatal morbidity and mortality. This study aims to conduct a non-systematic review of perinatal adverse events of fetuses with late-onset IUGR and selective changes in middle cerebral artery (MCA) Doppler. A literature search was performed using the PubMed database. A total of 25 references, which were the basis for this article was obtained. It concludes the middle cerebral artery has a particular value in the identification and prediction of adverse outcomes in these fetuses, which has an increased risk of abnormal neurological performance at birth and at two years of age.(AU)


Assuntos
Humanos , Feminino , Gravidez , Ultrassonografia Doppler Transcraniana , Artéria Cerebral Média/fisiopatologia , Artéria Cerebral Média/diagnóstico por imagem , Retardo do Crescimento Fetal/fisiopatologia , Retardo do Crescimento Fetal/diagnóstico por imagem , Doenças Placentárias/diagnóstico por imagem , Bases de Dados Bibliográficas , Assistência Perinatal/métodos , Desenvolvimento Fetal , Dilatação Patológica , Cérebro/irrigação sanguínea
7.
Femina ; 36(9): 585-587, set. 2008.
Artigo em Português | LILACS | ID: lil-505752

RESUMO

A Medicina Baseada em Evidências (MBE) surgiu nos anos 1990 com a idéia básica de se tornar um novo paradigma assistencial e pedagógico na área médica. Com o tempo, muito da sua proposta inicial foi deturpada ou superestimada, o que levou a sérios questionamentos de seus limites por alguns dos seus próprios fundadores. Este artigo tem por objetivo trazer para a área de ginecologia e obstetrícia uma discussão já realizada em outros campos da Medicina como a epidemiologia e a saúde pública.


The Evidende-Based Medicine (EBM) appeared in years 1990 as the basic idea of being a new assistential and pedagogical paradigm in medical area. With the time, much of its initial proposal become misunderstanding or overestimated, that took serious questions about EBM limits by some of its own founders. This article has the objective to bring to gynecology and obstetric area a discussion already done in others medicals fields as epidemiology and public health.


Assuntos
Tomada de Decisões , Ética Médica , Ginecologia , Medicina Baseada em Evidências/tendências , Obstetrícia , Educação Médica/tendências
8.
Rev. bras. ginecol. obstet ; 28(4): 238-243, abr. 2006. tab
Artigo em Português | LILACS, BVSAM | ID: lil-447903

RESUMO

OBJETIVO: avaliar a associação da relação sístole ventricular/atrial (S/A) do ducto venoso (DV) com resultados perinatais em fetos prematuros com centralização de fluxo à dopplervelocimetria. MÉTODOS: o estudo foi delineado como um estudo observacional, transversal, com os dados colhidos de forma prospectiva. A relação S/A do DV foi estudada em 41 fetos centralizados com idade gestacional (IG) entre 25 e 33ª semana completa, no período de novembro de 2002 a julho de 2005. Os recém-nascidos foram acompanhados até o 28° dia pós-parto na UTI da Clínica Perinatal Laranjeiras, buscando-se complicações neonatais. A população de estudo foi dividida em dois grupos a partir do resultado do DV. Foram incluídos no grupo normal os fetos com relação S/A menor ou igual a 3,6 e no grupo alterado aqueles com valores de S/A maiores que 3,6. A comparação entre os grupos foi realizada com os testes estatísticos de Mann-Whitney, chi2 e exato de Fisher. Todos os resultados foram considerados estatisticamente significativos se p<0,05. Foram avaliados a IG ao nascimento, peso ao nascer e índice de Apgar menor que 7 no 5° minuto. Os parâmetros perinatais avaliados foram: natimortalidade, neomortalidade, convulsão, hemorragia intraventricular, necessidade de surfactante, uso de respirador, disfunção miocárdica, enterocolite necrotizante e permanência na UTI após o período neonatal. RESULTADOS: dos 41 fetos incluídos, 26 (63,4 por cento) não apresentaram alteração da relação S/A do DV, ao passo que 15 (36,6 por cento) fetos cursaram com a relação S/A do DV alteradas (>3,6). Não houve diferença significativa entre os grupos quanto à IG ao nascimento e Apgar <7. Encontrou-se associação significante entre o grupo com DV alterado e mortalidade neonatal (p=0,049; teste exato de Fisher). Quanto às demais variáveis estudadas não foi observada diferença entre os dois grupos. CONCLUSÃO: os nossos resultados sugerem que a anormalidade do fluxo no DV detectada pela...


PURPOSE: to evaluate the relationship between S/A ratio in ductus venosus (DV) and perinatal outcomes in fetuses with brain sparing reflex. METHODS: the study was designed as an observational, sectional study with prospectively collected data. Forty-one fetuses with brain sparing reflex and gestational age between 25 and 33 weeks were studied between November 2002 and July 2005. The newborns were observed during the neonatal period in the intensive care unit of "Clínica Perinatal Laranjeiras" in order to find adverse outcomes. The study population was divided into two groups according to DV assessment. In the normal group all the fetuses with S/A ratio values of 3.6 or less were included, and in the abnormal group the fetuses with values of S/A ratio greater than 3.6. The statistical analysis was performed by the Mann-Whitney U-test, chi2 test and Fisher exact test. The results were considered significant when p<0.05. Gestational age, birth weight and Apgar score less than 7 at 5 min were evaluated. Perinatal outcome parameters were: intrauterine death, neonatal mortality, seizures, intraventricular hemorrhage, leukomalacia, need of surfactant, mechanical ventilation, myocardical failure, necrotizing enterocolitis, and length of stay in the intensive care unit. RESULTS: among the assessed 41 fetuses, 26 (63.4 percent) showed normal DV S/A ratio and the other 15 (36.6 percent) developed an abnormal DV S/A ratio (>3.6). There was no statistically signicant difference between the groups according to gestational age at delivery and Apgar <7. The only significant association was between abnormal DV S/A ratio and neonatal death (p=0.049; Fisher's exact test). No statistically significant association was observed for the other studied variables. CONCLUSIONS: our results suggest that abnormal DV blood flow detected by Doppler examination is not associated with adverse perinatal outcomes, except for neonatal mortality. This association may be...


Assuntos
Gravidez , Humanos , Feminino , Estudos Retrospectivos , Fluxometria por Laser-Doppler , Sangue Fetal , Sofrimento Fetal
9.
Femina ; 33(9): 705-708, sept. 2005.
Artigo em Português | LILACS | ID: lil-458514

RESUMO

A Síndrome de Down é a anormalidade cromossômica viável mais comum ao nascimento. Sua incidência na América do Sul é de 14,6 por 10.000 nascidos vivos. Neste artigo revemos as principais estratégias para o rastreamento bioquímico da Síndrome de Down, considerando o desempenho dos testes e sua aplicabilidade na prática clínica


Assuntos
Humanos , Feminino , Gravidez , alfa-Fetoproteínas , Estriol , Gonadotropina Coriônica Humana Subunidade beta/sangue , Inibinas , Biomarcadores/sangue , Primeiro Trimestre da Gravidez , Proteína Plasmática A Associada à Gravidez , Síndrome de Down/diagnóstico , Síndrome de Down/epidemiologia
10.
Femina ; 33(5): 379-383, maio 2005. ilus
Artigo em Português | LILACS | ID: lil-432647

RESUMO

Este artigo propõe a sistematização da propedêutica fetal em gestações de alto-risco com base em seis modelos de agravo fetal: modelo obstrutivo-toxêmico, modelo anêmico, modelo metabólico, modelo infeccioso, modelo umbilical e modelo de membrana. Nesse contexto podemos dispor de testes simples e bastante intuitivos, como a movimentação fetal, e também de testes mais sofisticados, como a dopplervelocimetria arterial e venosa. Na solicitação de cada exame estaremos considerando sua adequação ao processo fisiopatológico subjacente, bem como a necessidade de otimização dos recursos habitualmente utilizados. É importante ressaltar que não há consenso na literatura sobre esse tópico; entretanto, parece claro que cada situação tem um exame com maior acurácia e que os testes apresentam diferentes desempenhos nas diferentes patologias


Assuntos
Feminino , Gravidez , Humanos , Complicações na Gravidez/prevenção & controle , Diagnóstico Pré-Natal/métodos , Sofrimento Fetal , Gravidez de Alto Risco , Ultrassonografia Doppler , Viabilidade Fetal , Hipóxia
11.
Femina ; 32(8): 681-688, set. 2004. tab
Artigo em Português | LILACS | ID: lil-404853

RESUMO

Este artigo tem o objetivo de fornecer uma revisão sobre o parto prematuro.Foram revistos estudos recentes sobre fatores de risco de prematuridade,eficácia de agentes tocolíticos e medidas preventivas para o trabalho de parto prematuro,enfocando especialmente a prática obstétrica atual.A conduta na ruptura prematura das membranas ovulares,a via de parto na gestação prematura e o uso de novas drogas tocolíticas também são abordadas no presente artigo


Assuntos
Humanos , Feminino , Corticosteroides , Antibacterianos , Ruptura Prematura de Membranas Fetais , Incidência , Trabalho de Parto Prematuro , Fatores de Risco
12.
Rev. bras. ginecol. obstet ; 26(5): 355-361, jun. 2004. tab, graf
Artigo em Português | LILACS | ID: lil-363335

RESUMO

OBJETIVO: estabelecer o ponto de corte a partir do qual seja possível identificar fetos prematuros com centralização do fluxo sangüíneo que apresentem gasometria anormal. MÉTODO: foi realizado estudo observacional transversal, cuja população consistia de 60 gestantes com fetos centralizados (relação umbílico-cerebral maior que 1), com idade gestacional entre 25 e 33 semanas. O ducto venoso foi identificado com auxílio da dopplerfluxometria colorida e obtida a relação S/A a partir do sonograma (relação entre a velocidade de pico da sístole ventricular e a velocidade de pico da sístole atrial). Imediatamente após a cesariana foi colhida amostra de sangue da veia umbilical para gasometria. Os conceptos foram classificados de acordo com a análise gasométrica e considerados anormais quando pH <7,20 e BE < -6 mmol/l. Após o cálculo da sensibilidade e especificidade para cada ponto de corte foi construída a curva ROC (receiver operator characteristic). RESULTADOS: foram selecionadas 60 gestantes no período de janeiro de 1998 a janeiro de 2003. No momento do estudo a idade gestacional variou entre 25 e 33 semanas, média de 29,7 semanas (±1,8 semanas). Todos os fetos apresentavam-se centralizados; dentre eles 14 apresentavam gasometria anormal ao nascimento e 46 apresentavam gasometria normal. A prevalência de resultados de fetos com gasometria anormal no material estudado foi de 23,33 por cento. Observou-se associação significativa entre o resultado anormal do ducto venoso e gasometria anormal ao nascimento (chi2 = 784,44, p < 0,00001). O ponto de corte da relação S/A (onde a curva ROC "muda de tendência") foi 3,4. CONCLUSÃO: a análise da relação S/A do ducto venoso se mostra adequada para a predição não invasiva de gasometria anormal em fetos prematuros, centralizados, quando os valores são superiores a 3,4.


Assuntos
Humanos , Feminino , Gravidez , Desenvolvimento Embrionário e Fetal , Ultrassonografia Doppler , Gasometria , Gravidez de Alto Risco
13.
J. bras. ginecol ; 108(11/12): 413-6, nov.-dez. 1998. ilus
Artigo em Português | LILACS | ID: lil-235216

RESUMO

A prenhez abdominal é rara, e representa aproximadamente 1 por cento de todas as gestaçöes ectópicas. Os autores apresentam um relato de caso prenhez abdominal em uma paciente de 27 anos, com 12 semanas de gestaçäo. A mesma havia sido submetida a uma interrupçäo voluntária da gestaçäo (IVG) após a OVG, a paciente deu entrada ultra-sonográfico, foi feito diagnóstico de prenhez abdominal evolutiva e sangue livre na cavidade. Os autores propöem uma discussäo sobre o tema e desenvolvem uma revisäo de literatura


Assuntos
Feminino , Gravidez , Adulto , Gravidez Abdominal , Gravidez Abdominal/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA